RETURN TO FACTORY
PLEASE NOTE: To comply with Health and Safety requirements, the instrument must be clean and
safe to handle and accompanied by a formal statement to that effect duly signed by an authorised officer
of the Company.
Any instrument returned without certification will be quarantined and no action will occur until cleared. It
may ultimately be returned to you and subject to a transportation charge.
MAINTENANCE
Routine Inspection: Not required except for periodic inspection of the cable and connector to
ensure that these are neither damaged nor softened by incompatible liquid.
TABLE 1
CONNECTIONS 528 SERIES
4-20mA VOLTAGE
MODEL CODE CE CONNECTOR
IN+ IN- EARTH IN+ COM OUT+ EARTH
528 B3 Yes 10-6P A B E A C B E
528 VA Yes IP66 Cable R BL Drain R W Y Drain
528 UA Yes
Molded
Immersible
R BL Drain R W Y Drain
OUTPUT
SUPPLY
VOLTAGE
OUTPUT
SUPPLY
VOLTAGE
11 4 to 20mA 7 to 35V d.c. 24 0.5 to 5.5V 7 to 35V d.c.
28 1 to 6V 7.5 to 35V d.c. 2B 0 to 5V 6.5 to 35V d.c.
2R 1 to 11V 12.5 to 35V d.c. 2C 0 to 10V 11.5 to 35V d.c.
27 1 to 5V 6.5 to 35V d.c.
159 Swanson Road, Boxborough, MA 01719-1304
Tel: 800-257-3872 / 978-263-1400
OP528 Rev A 11/03